Optical scale series KD

The linear optical readers series KD are accurate and reliable, especially suited for applications in severe industrial environments.

They can be profitably employed on machine tools (CNC, boring machines, planomillers, vertical lathes, punching machines…..) and on operating and automatic machines (eg. bending presses, cutting machines, beading machines).
Different reading resolutions are at disposal: 0.1, 0.01, 0.005 or 0.001 mm.
The measuring strokes range from 250 to 6500 mm in compact size, over 6500 in the modular version.

Mechanical specificationsKD10KD100KD200KD1000
Caseextrused aluminium
Measuring elementout of stainless steel with thermal compensation
Operating principlephotoelectric reading by reflection
Dimensions23 x 56,7 mm
Total dimensionsstroke + 150 mm
Grating pitch400 µm40 µm20 µm40 µm with inside divider by 10
Reading resolution after the external electronic quadrupling0.1 mm0.01 mm0.005 mm0.001 mm
Protectionsanti-oil double gum sealing
Accuracy (at 20°C)± 0.010 mm/m± 0.005 mm/m± 0.003 mm/m± 0.003 mm/m
Max. speed120 m/min80 m/min60 m/min25 m/min
Max. acceleration40 m/sec.230 m/sec.230 m/sec.225 m/sec.2
Thermal expansionppm/°C/m = ± 10,6 T rif.20°C ±0,1°C
Vibration resistance (10÷2000 Hz)100 m/sec.2
Shock resistance (11 ms)= 150 m/sec.2
Operating temperature0÷50° C relative humidity 20-80%
Stocking temperature-20÷70 °C
Protection degreestandard IP54, pressured type IP64
Electrical SpecificationsKD10KD100KD200KD1000
Zero pulse1 zero reference at half measuring length (other positions on request)- type 1Z
Supplystandard: 12Vdc - 40 mA / on request: 5 Vdc 65 mA5Vcc 65mA
Output signals2 square waves 90° degree out of phase
Electronic outputsNPN pull-up collector/ optional 5 Vdc line driverline driver 5Vcc
Connectionsstandard cable with metal sheat 4 mt long