Encoder MEM – BUS EtherNet/IP

Multiturn encoders with EtherNet/IP interface – UL Listed

Based on the industrial Ethernet communication protocol, EtherNet/IP™ interface allows for a steady, flexible and fast communication between control systems and peripheral devices (i.e. sensors and actuators).

Elap encoders MEM-Bus EtherNet/IP can be easily integrated in any EtherNet/IP net, as they comply with all EtherNet/IP interface requirements, according to directives IEC61784-1. The encoder features the encoder profile 22H according to CIP™ protocol specifications.The encoders are ODVA conformant certified, including CIP Sync certification.

The encoders parameters – steps/revolution, preset number, rotation direction, speed/position alarm thresholds, unit – are set via TCP/IP. The measuring unit can be modified run-time. Besides the standard Assembly Objects 1,2,3, Elap encoder supports the proprietary object 110, granting a comprehensive view of parameters and alarms relating to speed and position. IP addressing  can be set both by rotary switches and via software (DHCP/BOOTP)

4 two-color signalling LEDs provide the diagnostic information about the device status in the net. The encoder supports the DLR (Device Level Ring) functionality, granting continuity in operation even in case of net interruptions.

MEM-Bus encoders are supplied in multiturn version with 29 bit resolution (8192 steps/revolution x 65536 revolutions).

Different mechanical versions are available to satisfy all application requirements: square flanged, round flanged with servo coupling, and with hollow shaft to couple directly to a motor shaft; all the types offer different options for the shaft/hole diameter. The electrical connection is by 3 M12 connectors.

The stout aluminium case ensures a high protection degree, so that it is possible to apply MEM-Bus encoders in severe industrial environments.

The innovative electronic construction technology – involving no mechanical gear –allows to reach high acceleration and speed values and grants the transducer long life.

MEM-Bus EtherNet/IP are UL certified for the Canadian and United States market.


TECHNICAL SPECIFICATIONS

  • Fieldbus interface: EtherNet/IP
  • CIP™ Protocol, encoder profile 22H
  • CIP Sync protocol
  • Synchronous Real Time transmission
  • Parameters entering via TCP/IT
  • IP addressing by dip-switch or via software (DHCP/BOOTP)
  • DLR (Device Level Ring) function
  • Standard Assembly Objects 1, 2, 3
  • Proprietory Object 110
  • Supply 10÷30  Vdc  2.5 W
  • Resolution 29 bit
  • Steps/revolution: 8192/13 bit
  • Revolutions no.: 65536/16 bit
  • Data memory > 20 years*
  • Several configurations available
  • Aluminium case
  • Protection degree: IP67 – Shaft side IP65

*No motion, power off


SETTABLE PARAMETERS

  • Steps/revolution
  • Revolutions number
  • Preset
  • Rotation direction
  • Measuring unit

STATE INDICATORS

  • 4 signalling LEDs for:
  • Link 1
  • Link 2
  • Net
  • Mod
  • Series MEM520 - Bus

    Ø 58 mm round flange
    Servo coupling
    Ø 50 mm centering mask
    Ø 6, 8 o 10 mm shaft

  • Series MEM540 - Bus

    Ø 58 mm round flange
    Ø 36 mm centering mask 3
    M4 holes at 120° on Ø 48 mm
    Ø 6, 8 o 10 mm shaft

  • Series MEM440 - Bus

    Hollow shaft for motor mounting
    Ø 8, 10, 12, 14, 15 mm hole

  • Series MEM450 - Bus

    Hollow shaft for motor mounting
    Ø 8, 10, 12, 14, 15 mm hole
    Fixing by elastic support

  • Series MEM620 - Bus

    63.5×63.5 mm square flange
    Ø 31.75 mm centering mask
    Ø 6, 8 o 10 mm shaft

Download: Encoder MEM – BUS EtherNet/IP